Would the ranking survive another 98 traces? A measurement reread of the decision-model data
Hamel Husain and Antaripa Saha published the data behind their decision-model comparison. A measurement reread shows what 98 traces can and cannot settle, and five steps that would settle the next one.
Hamel Husain and Antaripa Saha did something that lets any reader check their work. With "How To Use Decision Models for Evals" (Husain and Saha, 2026), they published the scores, the labels and a split-by-split threshold audit. The data covers six decision models on 98 production traces from an apartment-leasing agent. Their advice holds up. Don't trust the 0.50 default. Tie the threshold to what a miss and a false alarm cost you. Test calibration instead of assuming it. Their footnotes say plainly what the results do not establish.
Because they shared the data, anyone can ask the next question. If you drew another 98 traces from the same agent, would OpenAI Decisions still come out on top?
On these 98 traces, the data cannot yet say. Below is what their JSON shows when you treat it as a measurement problem, and five steps that would let the next comparison settle it.
The spread in the JSON answers a different question
The post reports OpenAI Decisions at an F1 of 0.87 for 3.72 cents per 100 eval runs. Perplexity Decider reaches 0.79 for 0.82 cents. "For this particular dataset," the authors write, "OpenAI had breakout performance at a higher cost." The JSON gives a held-out F1 standard deviation of 0.005 to 0.018 per model.
That standard deviation is the variation across 100 re-splits of the same 98 traces. It tells you how much the choice of folds matters. It does not tell you how much the result would move on a new sample of traces. A buyer of an eval model is asking that second question (Bates et al., 2024).
To ask it, I resampled the traces themselves. I used a paired bootstrap with 2,000 resamples. Every model was scored on the same resampled traces, with each model's threshold held at its tuned value. Figure 1 shows the result.

OpenAI minus Perplexity is +0.053 on F1, with a 95% interval of -0.008 to +0.115. OpenAI minus Liquid d1-ultra is +0.061, from -0.003 to +0.132. The AUC gaps tell the same story: -0.011 to +0.157 against Perplexity and -0.018 to +0.120 against d1-ultra. An exact McNemar (1947) test on per-trace correctness finds 12 traces where only OpenAI was right and 5 where only the other model was right. That gives p = 0.14 for both comparisons.
Three caveats keep these intervals honest. The F1 point values come from thresholds tuned on all 98 traces (OpenAI 0.878, Perplexity 0.825), a little above the post's held-out figures. Holding thresholds fixed ignores the uncertainty in choosing them, so the true intervals are, if anything, wider. Six models make 15 pairwise comparisons. At a Bonferroni level of 0.05 / 15 = 0.0033, even the one F1 gap that excludes zero (OpenAI against Clef Flash, McNemar p = 0.009) does not hold up.
The cost difference is real: OpenAI costs about 4.5 times as much per run. The performance difference among the three candidates is not established at this sample size, which is different from saying it is absent.
How many labels would settle it
The answer is a sample size, and you can compute it before anyone labels a trace.
With 61 labeled failures, the smallest recall difference the set can detect at 80% power and a two-sided 0.05 level is about 0.18 when recall sits near 0.85. Near 0.80 it is about 0.20 (unpaired comparison). Pairing helps, because every model scores the same traces. The observed accuracy gap between OpenAI and either candidate is 0.071, with 17.3% of traces scored differently by the two models. Detecting a gap that size at 80% power needs about 265 paired traces, close to three times this set.
The practical rule follows directly. Decide the smallest difference that would change your vendor choice, then size the label set to detect it.
The 80/80 minimum, out of sample
The post sets a sensible bar: at least 80% precision and 80% recall for an alerting use case. It reports that Perplexity, Liquid d1-ultra and OpenAI Decisions "meet our requirements."
Footnote 9 explains that the authors "identify candidates from the full-sample precision-recall curves," and that the minimums "do not guarantee the same performance on new examples." Their own held-out numbers bear that out. Held-out precision is 0.754 for Perplexity and 0.759 for d1-ultra, both under 0.80. The 80/80 constraint could not be met in 36 of 100 training splits for Perplexity and 29 for d1-ultra. OpenAI alone met both minimums held out (precision 0.869, recall 0.862) and never needed a fallback.
The repair is cheap. Choose candidates inside the outer folds, or lock away a test set, and report the share of held-out folds that meet both minimums.
Every threshold carries a judge's severity
Every model saw the same rubric and the same traces. Figure 2 shows where each model's best threshold landed.

The thresholds run from 0.055 for Clef Flash to 0.72 for OpenAI. Part of that spread is each model's score scale. Part of it is how readily each model calls a trace a failure, which rater measurement calls severity. The rubric invites it. Its key terms, "substantive," "materially" and "meaningful," come with no boundary examples, so each model draws its own line. Per-model threshold tuning folds scale and severity into one number per model. Nothing in the recipe can separate the two, compare them across models, or check whether a model's severity holds steady from easy traces to hard ones.
Platt scaling (Platt, 2000) has the same blind spot. It is a good tool for what the post uses it for: two parameters, hard to overfit, fitted out of fold. The authors report honestly that it made OpenAI slightly worse. Three limits matter for anyone who wants to reuse the probabilities.
- It is monotone, so it cannot change AUC or any tuned-threshold F1. A model that separates failures poorly still separates them poorly.
- Its intercept carries this sample's 62% failure rate. A "calibrated" 0.80 here is not a calibrated 0.80 in a production stream where 10% of traces fail.
- The changes for the already well-calibrated models are small against sampling noise. Jev moves from a Brier score of 0.187 to 0.188, d1-ultra from 0.173 to 0.172, and OpenAI from 0.159 to 0.164. The bootstrap interval on OpenAI's raw Brier score alone runs from 0.104 to 0.219. Niculescu-Mizil and Caruana (2005) discuss when Platt scaling helps.
Many-facet Rasch measurement (Linacre, 1994) treats the same problem as measurement. In its simplest form for this task, the log-odds that judge j flags trace n is F(n) minus C(j). Here F(n) is the trace's location on the failure scale and C(j) is the judge's severity, its reluctance to flag. You can add a rubric facet for each criterion. Each parameter gets its own standard error. Fit statistics flag a judge whose severity shifts between easy and hard traces. When the data fit the model, comparisons between traces do not depend on which judges happened to rate them (Rasch, 1980, Engelhard and Wind, 2018). Anchor traces let a new judge or a new prompt version link to the existing scale (Kolen and Brennan, 2014).
This extends published work. Barney, Wind and Krishna (2026) used many-facet Rasch measurement to estimate the severity of LLM raters that scored ethical persuasion text. Barney and Barney (2024) set out the case for combining metrology and psychometrics in LLM-based measurement. The decision-model JSON already has six judges scoring the same 98 traces, which is a connected design. A many-facet analysis of it is the natural next step. I did not run it for this post.
The word "calibration" also means two different things. In statistics, it means predicted probabilities match observed frequencies on a sample. In metrology, it means relating an instrument's reading to a reference value with a stated uncertainty. That relation is documented so that each result traces back through an unbroken chain to the reference. That chain is metrological traceability (JCGM, 2012). Platt scaling is the statistical kind.
The reference labels are a rater too
Footnote 3 is candid about how the reference was built. The 61 failures are "39 failures from the original human review plus 22 discoveries from Braintrust and Arize that we manually validated." Against the final reference, the original review caught 39 of 61, a recall near 0.64.
Two consequences follow. Failures that LLM-based tools find easily are over-represented, which can flatter LLM-based classifiers. The 37 negatives are "traces without a labeled failure," not traces confirmed clean, so some false positives may be real failures. Diagnostic-accuracy research has a long literature on imperfect reference standards for this situation (Reitsma et al., 2009). The models were also scored against labels made under different criteria from the rubric they were given.
The fix is more labeling. Two or more blind raters relabel all 98 traces with the exact rubric the models saw. The team reports their agreement and places the human raters on the same scale as the models, instead of treating them as ground truth.
The number your dashboard will show
A natural next use of a tuned decision model is a production failure rate. The label counts decide how much you can trust that rate.
Take OpenAI at its tuned threshold: sensitivity 54/61 = 0.885 and specificity 29/37 = 0.784. Suppose it flags 30% of 1,000 production traces. The Rogan and Gladen (1978) correction gives a true failure rate of 0.125, with a standard error of 0.091 and a 95% interval of roughly 0 to 0.30. About 94% of that variance comes from specificity, estimated on 37 labeled passes. More production traces will not narrow the interval. More labeled passes will.
Five steps to add to the recipe
Keep every step in the original recap. Then add these, which cost labels rather than model calls.
1. Report a paired interval on every model-versus-model gap, resampling traces, not folds.
2. Size the label set from the smallest difference that would change your decision, before you label.
3. Select candidates inside the folds or on a locked test set, and report how often held-out folds meet your minimums.
4. Label passes as carefully as failures. The negatives set the precision of every corrected rate.
5. Treat every judge, human or model, as a rater with an estimated severity, and keep anchor traces so the next model version lands on the same scale.
At XLNC we build these ideas into AIM. AIM estimates each judge's severity as its own facet, with a standard error. A buyer picks the Fast or the Full setting. Full scores with the panel of credentialed judges that has the highest measured capability index (MCpk) for the range, at 95% certainty. No judge holds a credential at complexity levels 10 to 12 yet.
The authors close on the right instinct: "it's important to measure things yourself." Measurement adds two things a tuned classifier lacks. One is a unit that means the same thing next month. The other is an interval that tells you when two numbers are really the same number. Publishing the data is what made this reread possible. More eval posts should do it.
---
I sent Hamel Husain this reanalysis on October 21, 2026, and invited corrections before publishing. I had not received a reply by publication. I will add any corrections he sends.
Methods note
Data: the three JSON files linked from the original post (chart-data.json, calibration-reliability-data.json, threshold-selection-audit.json), downloaded again and byte-checked on November 18, 2026. Bootstrap: 2,000 resamples of the 98 traces, seed 20261022, percentile intervals. Proportion intervals: Wilson (1927). Paired tests: exact McNemar on per-trace correctness at each model's tuned threshold. Power: normal-approximation formulas for two proportions (unpaired) and for McNemar (paired). The before-and-after Brier scores are the authors' own (their footnote 12). The bootstrap interval on raw Brier is ours. The analysis script is available on request.
References
- Barney, M., & Barney, F. (2024). Transdisciplinary measurement through AI: Hybrid metrology and psychometrics powered by large language models. In W. P. Fisher Jr. & L. Pendrill (Eds.), Models, measurement, and metrology extending the SI (pp. 103-132). De Gruyter. https://doi.org/10.1515/9783111036496-003
- Barney, M., Wind, S. A., & Krishna, V. (2026). Using large language models to evaluate ethical persuasion text: A measurement modeling approach. International Journal of Assessment Tools in Education, 13(1), 224-247. https://doi.org/10.21449/ijate.1788563
- Bates, S., Hastie, T., & Tibshirani, R. (2024). Cross-validation: What does it estimate and how well does it do it? Journal of the American Statistical Association, 119(546), 1434-1445. https://doi.org/10.1080/01621459.2023.2197686
- Engelhard, G., Jr., & Wind, S. A. (2018). Invariant measurement with raters and rating scales: Rasch models for rater-mediated assessments. Routledge. https://doi.org/10.4324/9781315766829
- Husain, H., & Saha, A. (2026, October 20). How to use decision models for evals. https://hamel.dev/blog/posts/decision-model-evals/
- Joint Committee for Guides in Metrology. (2012). International vocabulary of metrology: Basic and general concepts and associated terms (VIM) (3rd ed., JCGM 200:2012). https://www.bipm.org/documents/20126/2071204/JCGM_200_2012.pdf
- Kolen, M. J., & Brennan, R. L. (2014). Test equating, scaling, and linking: Methods and practices (3rd ed.). Springer. https://doi.org/10.1007/978-1-4939-0317-7
- Linacre, J. M. (1994). Many-facet Rasch measurement (2nd ed.). MESA Press. ISBN 0-941938-02-6
- McNemar, Q. (1947). Note on the sampling error of the difference between correlated proportions or percentages. Psychometrika, 12(2), 153-157. https://doi.org/10.1007/BF02295996
- Niculescu-Mizil, A., & Caruana, R. (2005). Predicting good probabilities with supervised learning. In Proceedings of the 22nd International Conference on Machine Learning (pp. 625-632). https://doi.org/10.1145/1102351.1102430
- Platt, J. C. (2000). Probabilistic outputs for support vector machines and comparisons to regularized likelihood methods. In A. J. Smola, P. J. Bartlett, B. Schölkopf, & D. Schuurmans (Eds.), Advances in large margin classifiers. MIT Press. ISBN 0-262-19448-1
- Rasch, G. (1980). Probabilistic models for some intelligence and attainment tests (Expanded ed.). University of Chicago Press. ISBN 0-226-70554-4
- Reitsma, J. B., Rutjes, A. W. S., Khan, K. S., Coomarasamy, A., & Bossuyt, P. M. (2009). A review of solutions for diagnostic accuracy studies with an imperfect or missing reference standard. Journal of Clinical Epidemiology, 62(8), 797-806. https://doi.org/10.1016/j.jclinepi.2009.02.005
- Rogan, W. J., & Gladen, B. (1978). Estimating prevalence from the results of a screening test. American Journal of Epidemiology, 107(1), 71-76. https://doi.org/10.1093/oxfordjournals.aje.a112510
- Wilson, E. B. (1927). Probable inference, the law of succession, and statistical inference. Journal of the American Statistical Association, 22(158), 209-212. https://doi.org/10.1080/01621459.1927.10502953